NORTH AMERICAN Torus Power PRODUCTS

WALL MOUNT SERIES power transformer

WALL MOUNT SERIES

Technology

WM RM Series

  • Toroidal Isolation
  • Noise Filtering
  • High Instantaneous Current Capability
  • Series Mode Surge Suppression

WM AVR Series Has All of the Above, Plus

  • Automatic Voltage Regulation
  • Smart Ethernet

WM AVR2 Series Has All of the Above, Plus

  • Custom Control

Description

Torus Power Wall Mount (WM) Models provide great flexibility for custom installations, and new construction. Dedicated lines can be run to install the power outlets where needed. Select the appropriate power level – ratings of 45A, 60A, 75A and 100A are available (90 Amp for AVR / AVR2 models).

Choose the WM model with the features needed; AVR2 models for individually controlled outlets, AVR models for basic monitoring, and RM models for straight power conditioning and protection. (Features are detailed separately.)

WM units are designed for 240V input. Units can also be supplied with 208V inputs for 3-phase systems. WM units are provided with 20A output breakers. Alternatively, WM units can be supplied with terminal blocks to enable direct feed to subpanel.

International Models of various voltages and frequencies can also be supplied.

 

Features

AVR2 has all features of AVR
AVR SERIES FEATURES
  • Password protection control
  • Automatic email notification on fault condition
  • Series mode surge suppression — protects against lighting strikes
  • Automatic Voltage Regulationxxx — maintain stable voltage conditions
  • RS-232 control — compatible with Crestron and other control systems
  • Switch-On Safety Delay (5 seconds) when power turned on / restored
  • Cloud based monitoring and control through Nuage Nine, ihiji, and other systems in future
  • IP addressable with built-in web browser interface – allows remote monitoring and control
  • Front panel display shows voltage conditions (input / output voltage), current draw, and IP address
  • Toroidal Isolation Power Conditioning—provide the ultimate in Clean Power performance

Plus the Following Features

  • Sequencing via scheduling feature
  • Individually addressable outlet zones
  • Power-up sequencing with selectable delay time between zones
  • Parameters allow one week repeating schedule with up to 6 events per day per zone
  • Automatic reboot feature to allow remote restart of routers and modems if internet connection lost
  • Scheduling features let automatic control on/off of any outlet zone according to user-defined schedule.
  • Schedule remains active even when internet connection is lost, so long as system power maintained.

SPECIFICATIONS

MODEL WM 45 BAL WM 60 BAL WM 75 BAL WM 100 BAL
CHASSIS WALL MOUNT
INPUT VOLTAGE 240 VAC
OUTPUT VOLTAGE 120 VAC
INPUT CURRENT LIMITING (FUSES) 2 X 25A 2 X 30A 2 X 40A 2 X 50A
OUTPUT CURRENT (A) 45 60 75 100
POWER RATING (VA) 5,400 7,200 9,000 12,000
FREQUENCY (Hz) 60
OUTPUT BREAKERS 3 X 20A 5 X 20A
WEIGHT (LBS) 164 191 219 233
WEIGHT (KG) 74.5 86.5 99.5 105.5
SIZE (H X W X D) INCHES 26.5 X 20.7 X 10.3
SIZE (H X W X D) MM 673 X 526 X 261
MODEL WM 45 BAL AVR WM 60 BAL AVR WM 75 BAL AVR WM 90 BAL AVR
CHASSIS WALL MOUNT
INPUT VOLTAGE 240 VAC
OUTPUT VOLTAGE 120 VAC +/- 5 V
INPUT CURRENT LIMITING (FUSES) 2 X 25A 2 X 30A 2 X 40A 2 X 45A
OUTPUT CURRENT (A) 45 60 75 90
POWER RATING (VA) 5,400 7,200 9,000 10,800
FREQUENCY (Hz) 60
OUTPUT BREAKERS 3 X 20A 5 X 20A
WEIGHT (LBS) 175 202 228 233
WEIGHT (LBS) 79.5 91.5 103.5 105.5
SIZE (H X W X D) INCHES 32.5 X 24.7 X 10.3
SIZE (H X W X D) MM 826 X 627 X 261
MODEL WM 45 BAL AVR2 WM 60 BAL AVR2 WM 75 BAL AVR2 WM 90 BAL AVR2
CHASSIS WALL MOUNT
INPUT VOLTAGE 240 VAC
OUTPUT VOLTAGE 120 VAC +/- 5 V
INPUT CURRENT LIMITING (FUSES) 2 X 25A 2 X 30A 2 X 40A 2 X 45A
OUTPUT CURRENT (A) 45 60 75 90
POWER RATING (VA) 5,400 7,200 9,000 10,800
FREQUENCY (Hz) 60
OUTPUT BREAKERS 3 X 20A 5 X 20A
WEIGHT (LBS) 175 202 228 233
WEIGHT (KG) 79.5 91.5 103.5 105.5
SIZE (H X W X D) INCHES 32.5 X 24.7 X 10.3
SIZE (H X W X D) MM 826 X 627 X 261

More Wall Mount Series Information

 

All WM Series models are available with a Transient Voltage Surge Suppression (TVSS) device built into its signal path. The UL certified panel TVSS responds in under 5 nano-seconds and manages surges up to 80,000 Amps. The TVSS also offers additional noise filtration of EMI and RFI (40 dB typical).

Balanced Inputs Input Voltage also available at 208V for BAL products feeding from a 3 phase system. Balanced Power input current is drawn at one half the output current capacities. Balanced power input wiring should be installed by a qualified electrician.

TOT Series

RM Series

AVR Series

AVR2 Series

All In One Series

Floor Mount Series

Share This