NORTH AMERICAN Torus Power PRODUCTS
AVR SERIES
Technology
- Toroidal Isolation
- Noise Filtering
- High Instantaneous Current Capability
- Series Mode Surge Suppression
- Automatic Voltage Regulation
- Smart Ethernet
Description
Torus Power AVR models add Automatic Voltage Regulation to the standard Torus Power features, thereby enhancing protection against voltage sags, brownouts and surges. Ethernet connectivity and RS232 interface makes AVR models ideal for basic home monitoring applications.
Torus AVR will keep the output constant within the range of 115 Volts to 125Volts, with an input voltage of 90V to 130V. Between 85V to 90V, and between 130V and 135V, the regulation will be reduced.
Balanced Input is available on many Torus Power models, providing an additional stage of noise cancellation. Torus AVR with balanced input will keep the output constant within the range of 115 Volts to 125 Volts, with an input voltage of 170V to 270V.
Features
- IP addressable with built-in web browser interface – allows remote monitoring and control
- Password protection control
- Automatic email notification on fault condition
- RS-232 control — compatible with Crestron and other control systems
- Switch-On Safety Delay (5 seconds) when power turned on / restored
- Cloud based monitoring and control through ihiji, and other systems
- Front panel display shows voltage conditions (input / output voltage), current draw, and IP address

Torus Medical Grade Outlets on North American Models
Torus Power RM, AVR, and AVR2 series models use extra heavy duty medical grade outlets custom manufactured by Hubbell. These outlets provide greater contact force, reduced heat buildup, and redundant grounding, and are vastly superior to commercial grade outlets. Torus Power 15 Amp & 20 Amp Outlets are available for purchase.
SPECIFICATIONS
MODEL | TOT AVR |
FACEPLATE | BLACK ‘DRESS’ FACEPLATE INCLUDED |
CHASSIS | 2U |
INPUT | 90 – 130 VAC |
OUTPUT | 120 VAC +/- 5 V |
INPUT FUSE | 10A |
OUTPUT CURRENT | 10A |
POWER VA | 1200 |
FREQUENCY | 60 Hz |
NO. OUTLETS | 6 |
INLET | IEC 15A |
WEIGHT LB | 35.2 |
WEIGHT KG | 16 |
SIZE MM W X D X H | 318 x 101 x 369 |
SIZE IN W X D X H | 12.5 x 4.0 x 14.5 |
MODEL | AVR 15 | AVR20 |
FACEPLATE | 19″ RACK MOUNT (RK), 17″ SILVER (CS), 17″ BLACK (CB) | |
CHASSIS | 2U | |
INPUT | 90 – 130VAC | |
OUTPUT | 120 VAC +/- 5 V | |
INPUT FUSES | 1 X 15A | 1 X 20A |
OUTPUT CURRENT | 15A | 20A |
POWER VA | 1,800 | 2,400 |
FREQUENCY | 60 Hz | |
NO. OUTLETS | 10 | |
INLET | IEC 15A | IEC 20A |
WEIGHT LB | 56.4 | 95 |
WEIGHT KG | 25.6 | 43.2 |
SIZE MM WXDXH | 483X483X102 | 483X 483X203 |
SIZE IN WXDXH | 19X19X4 | 19X19X8 |
MODEL | AVR20 BAL | AVR 45 BAL | AVR60 BAL | AVR75BAL | AVR90 BAL | |||||
FACEPLATE | 19″ RACK MOUNT (RK), 17″ SILVER (CS), 17″ BLACK (CB) | |||||||||
CHASSIS | 4U | 5U | ||||||||
INPUT | 170 – 270 VAC | |||||||||
OUTPUT | 120 VAC +/- 5 V | |||||||||
INPUT FUSE | 1 X 10A | 2 X 25A | 2 X 30A | 2 X 40A | 2 X 45A | |||||
OUTPUT CURRENT | 20A | 45A | 60A | 75A | 90A | |||||
POWER VA | 2,400 | 5,400 | 7,200 | 9,000 | 10,800 | |||||
FREQUENCY | 60 Hz | |||||||||
NO. OUTLETS | 10 | 18 | 24 | |||||||
INLET | IEC 20A | TWIST LOCK 30A, 250V | TWIST LOCK 50A, 250V | |||||||
OUTPUT FUSES | 3 X 20 A | 5 X 20A | ||||||||
WEIGHT LB | 103 | 138 | 164 | 195 | 200 | |||||
WEIGHT KG | 47 | 62.5 | 74.5 | 88.5 | 90.5 | |||||
SIZE MM W X D X H | 483 X 483 X 203 | 483 X 559 X 249 | 483 X 660 X 249 | |||||||
SIZE IN W X D X H | 19 X 19 X 8 | 19 X 22 X 9.8 | 19 X 26 X 9.8 | |||||||
Input Voltage also available at 208V for BAL products feeding from a 3 phase system. | ||||||||||
Balanced Input current is drawn at one half the output current capacities. | ||||||||||
Balanced Input wiring should be installed by a qualified electrician. |