Torus
Power International RM 8 AVR and CS 8 AVR models provide
8 Amp
capability and 230-240V Input / 230-240V Output.
Power Conditioning and Voltage Regulation combined in one
efficient high-performance unit.
Torus AVR
provides stable output voltage to keep equipment running in the
optimal range of
240VAC ± 10V ( UK
Models) and
230VAC ± 10V
(
German and Australian Models.)
AVR
Series uses a microprocessor to monitor and control incoming
voltages.
Torus Power AVR
(Automatic Voltage Regulation) is a full-feature power conditioner, isolating and protecting your system.
Like all Torus Power products, the AVR series provides true
isolation (using massive toroidal transformers) .
Torus Power AVR series protects all connected
equipment from the risk of severe power line surges using
series-mode surge suppression.
|
|
Technical Specs
Input Voltage Range: 170VAC - 270VAC UK
Models, 160VAC - 260VAC German and Australian
ModelsFrequency Range: 47-53
Hz
Input Current Limiting:
8A Circuit Breaker Front Panel
Input (inlet) connector Rear panel: IEC 15A Inlet
Line Cord (included):
Input current rating: 8A
Output Voltage Range: 240VAC ± 10V (230V to 250V) UK Models,
230VAC ± 10V (220V to 240V) German and
Australian Models
Output Current Limiting: N/A
Output connector: 13A/250V UK Socket (5 Outlets)16A/250V
Ivory Continental European Socket GER (5 Outlets), 10A/250V
Interpower Socket AUS (5 Outlets)
Surge Suppression: Meets IEEE C62.41-1991:
Series mode type; built to withstand 6000 volts, 3000 amps for 1000
repeats; with clamping voltage of 2 volts above peak nominal
voltage.
Noise Reduction: Performs as low pass
filter, attenuating noise from 2kHz to 1mHz, with attenuation of 12
db/decade to 500 kHz.
Automatic Voltage Regulation: Uses
microprocessor based controller with 40Amp relays.
Interfaces: RS232, Ethernet via
built-in web browser
Triggers: 2 X 12V
Weight: 77lbs (35Kg)
19" Rack Mount Faceplate
Size (w x d x h) (mm): 483 x 565 x 159
17" Consumer Series Faceplate
Size (w x d x h) (mm): 432 x 556 x 162

|