- Provide
Clean AC Power and Surge Suppression that really works
- Available
in 2 styles - Rack Mount & CS (Silver or Black)
Torus RM 60 BAL and CS
60 BAL
Power Conditioners
Balanced 240V input is provided from two x 120V phases and supplies
highest power capability and noise cancellation. The toroidal
isolation transformer steps-down the 240V input to 120V to power
the equipment. Where 240V is unavailable, the higher power units
may be configured for 208V operation. Balanced 240V input does
not require the use of failure-prone Ground Fault Circuit Interruption
(GFCI) devices.
The models in the Custom Series should be professionally installed
by qualified electricians and/or CEDIA certified installers.
Technical Specification
Input Voltage and Frequency:
Selectable
240VAC (2 x 120VAC, Balanced) or 208VAC, Factory wired for 240VAC.
Selectable: 208VAC Range ± 10% (57-63)Hz
Input Current Limiting:
30A 2 X Fuses Rear Panel
Input (inlet) connector Rear panel: Twist-Lock 2 Pole 3 Wires
grounding 30A 250V NEMA L6-30P
Line Cord (included): Type E
(For
information on line cords, receptacles, and power inlets, see
Customer Care.)
Input current rating: 24A
Output voltage: 120V AC
Output Current Limiting: 20A 3 x Circuit Breaker Front Panel
Output connector: Medical Grade Duplex 20A (Qty 9) 18 Outlets
Surge Suppression: Meets IEEE C62.41-1991:
Series mode type; built to withstand 6000 volts, 3000 amps for 1000
repeats; with clamping voltage of 2 volts above peak nominal voltage.
Noise Reduction: Performs as low pass
filter, attenuating noise from 2kHz to 1mHz, with attenuation of
12 db/decade to 500 kHz.
Weight: 155lbs
(70.5Kg)
RM 60 BAL - 19" Rack Mount Faceplate
Size (w x d x h) (inch): 19 x 22 x 8
Size (w x d x h) (mm): 483 x
559 x 203
CS 60 BAL - 17" Consumer Series Faceplate
Size (w x d x h) (inch): 17
x 16 x 8.13 Size (w x d x h) (mm):
432 x 559 x 207
|