RM 100 BAL
Balanced 240V input is provided from two x 120V phases and supplies
highest power capability and noise cancellation. The toroidal
isolation transformer steps-down the 240V input to 120V to power
the equipment. Where 240V is unavailable, the higher power units
may be configured for 208V operation. Balanced 240V input does
not require the use of failure-prone Ground Fault Circuit Interruption
(GFCI) devices.
The models in the Custom Series should be professionally installed
by qualified electricians and/or CEDIA certified installers.

Rear Panel View
|
|
Input Voltage and Frequency: Selectable 240VAC (2 x 120VAC,
Balanced) or 208VAC, Factory wired for 240VAC. Selectable: 208VAC
Range ± 10% (57-63)Hz
Input Current Limiting:
50A 2 X Fuses Internal
Input (inlet) connector Rear panel: Twist-Lock 2 Pole 3 Wires
grounding 50A 250V
Line Cord (included): Type F
Input current rating: 40A
Output voltage: 120V AC
Output Current Limiting: 20A 5 x Circuit Breaker Front Panel
Output connector: Medical Grade Duplex 20A (Qty 12) 24 Outlets
Surge Suppression: Meets IEEE C62.41-1991:
Series mode type; built to withstand 6000 volts, 3000 amps for 1000
repeats; with clamping voltage of 2 volts above peak nominal voltage.
Noise Reduction: Performs as low pass
filter, attenuating noise from 2kHz to 1mHz, with attenuation of
12 db/decade to 500 kHz.
Weight: 220lbs
(100Kg)
Size (w x d x h)(mm): 19x23x9.75 (483x584x248) |