RM 60 BAL
CS 60 BAL
Provide Clean AC Power and Surge Suppression that really works
Available in 2 styles – Rack Mount & CS (Silver or Black)
Balanced 240V input is provided from two x 120V phases and supplies highest power capability and noise cancellation. The toroidal isolation transformer steps-down the 240V input to 120V to power the equipment. Where 240V is unavailable, the higher power units may be configured for 208V operation. Balanced 240V input does not require the use of failure-prone Ground Fault Circuit Interruption (GFCI) devices.
Input Voltage and Frequency: Selectable 240VAC (2 x 120VAC, Balanced) or 208VAC, Factory wired for 240VAC. Selectable: 208VAC Range ± 10% (57-63)Hz
Input Current Limiting: 30A 2 X Fuses Rear Panel
Input (inlet) connector Rear panel: Twist-Lock 2 Pole 3 Wires grounding 30A 250V NEMA L6-30P
Line Cord (included): Type E (For information on line cords, receptacles, and power inlets, see Customer Care.)
Output voltage: 120V AC
Output Current Limiting: 20A 3 x Circuit Breaker Front Panel
Output connector: Medical Grade Duplex 20A (Qty 9) 18 Outlets
Surge Suppression: Meets IEEE C62.41-1991: Series mode type; built to withstand 6000 volts, 3000 amps for 1000 repeats; with clamping voltage of 2 volts above peak nominal voltage.
Noise Reduction: Performs as low pass filter, attenuating noise from 2kHz to 1mHz, with attenuation of 12 db/decade to 500 kHz.
Weight: 155lbs (70.5Kg)
|
RM 60 BAL – 19" Rack Mount Faceplate |
|
|
CCS 60 BAL – 17" Consumer Series Faceplate |
|
CE Approved