NORTH AMERICAN Torus Power PRODUCTS

AVR SERIES

Technology

  • Toroidal Isolation
  • Noise Filtering
  • High Instantaneous Current Capability
  • Series Mode Surge Suppression
  • Automatic Voltage Regulation
  • Smart Ethernet

Description

Torus Power AVR models add Automatic Voltage Regulation to the standard Torus Power features, thereby enhancing protection against voltage sags, brownouts and surges. Ethernet connectivity and RS232 interface makes AVR models ideal for basic home monitoring applications.

Torus AVR will keep the output constant within the range of 115 Volts to 125Volts, with an input voltage of 90V to 130V. Between 85V to 90V, and between 130V and 135V, the regulation will be reduced.

Balanced Input is available on many Torus Power models, providing an additional stage of noise cancellation. Torus AVR with balanced input will keep the output constant within the range of 115 Volts to 125 Volts, with an input voltage of 170V to 270V.

 

Features

  • IP addressable with built-in web browser interface – allows remote monitoring and control
  • Password protection control
  • Automatic email notification on fault condition
  • RS-232 control — compatible with Crestron and other control systems
  • Switch-On Safety Delay (5 seconds) when power turned on / restored
  • Cloud based monitoring and control through ihiji, and other systems
  • Front panel display shows voltage conditions (input / output voltage), current draw, and IP address

Torus Medical Grade Outlets on North American Models

Torus Power RM, AVR, and AVR2 series models use extra heavy duty medical grade outlets custom manufactured by Hubbell. These outlets provide greater contact force, reduced heat buildup, and redundant grounding, and are vastly superior to commercial grade outlets. Torus Power 15 Amp & 20 Amp Outlets are available for purchase.

SPECIFICATIONS

MODEL TOT AVR
FACEPLATE BLACK ‘DRESS’ FACEPLATE INCLUDED
CHASSIS  2U
INPUT 90 – 130 VAC
OUTPUT 120 VAC +/- 5 V
INPUT FUSE  10A
OUTPUT CURRENT 10A
POWER VA 1200
FREQUENCY 60 Hz
NO. OUTLETS 6
INLET  IEC 15A
WEIGHT LB  35.2
WEIGHT KG  16
SIZE MM W X D X H 318 x 101 x 369
SIZE IN W X D X H 12.5 x 4.0 x 14.5
MODEL AVR 15 AVR20
FACEPLATE 19″ RACK MOUNT (RK), 17″ SILVER (CS), 17″ BLACK (CB)
CHASSIS 2U 4U
INPUT 90 – 130VAC
OUTPUT 120 VAC +/- 5 V
INPUT FUSES 1 X 15A 1 X 20A
OUTPUT CURRENT 15A 20A
POWER VA 1,800 2,400
FREQUENCY 60 Hz
NO. OUTLETS 10
INLET IEC 15A IEC 20A
WEIGHT LB 56.4 95
WEIGHT KG 25.6 43.2
SIZE MM WXDXH 483X483X102 483X 483X203
SIZE IN WXDXH 19X19X4 19X 19X8
MODEL AVR20 BAL AVR 45 BAL AVR60 BAL AVR75BAL AVR90 BAL
FACEPLATE 19″ RACK MOUNT (RK), 17″ SILVER (CS), 17″ BLACK (CB)
CHASSIS 4U 5U
INPUT 170 – 270 VAC
OUTPUT 120 VAC +/- 5 V
INPUT FUSE 1 X 10A 2 X 25A 2 X 30A 2 X 40A 2 X 45A
OUTPUT CURRENT 20A 45A 60A 75A 90A
POWER VA 2,400 5,400 7,200 9,000 10,800
FREQUENCY 60 Hz
NO. OUTLETS 10 18 24
INLET IEC 20A TWIST LOCK 30A, 250V TWIST LOCK 50A, 250V
OUTPUT FUSES 3 X 20 A 5 X 20A
WEIGHT LB 103 138 164 195 200
WEIGHT KG 47 62.5 74.5 88.5 90.5
SIZE MM W X D X H 483 X 483 X 203 483 X 559 X 249 483 X 660 X 249
SIZE IN W X D X H 19 X 19 X 8 19 X 22 X 9.8 19 X 26 X 9.8
Input Voltage also available at 208V for BAL products feeding from a 3 phase system.
Balanced Input current is drawn at one half the output current capacities.
Balanced Input wiring should be installed by a qualified electrician.